Entry DateAugust 15, 2021
Issue Number21-040-RAM
NameRion A Stann
AgencyPennsylvania State Police
AddressCommercial Vehicle Safety Division
1800 Herr St- Tent Building
Harrisburg, PA 17103
United States
Map It
Phone(570) 290-4938
EmailEmail hidden; Javascript is required.
Issue NameOOSC Flipchart, Part II, Item 1a. Brakes - Amendment to 20 % Brake Criteria Flipchart
Summary of Issue

The Level VI Out of Service Criteria has contradictory wording in Part II Items 1.a. and 1.b. based on the OOS requirements for Level VI.

Justification or Need

An inspector that is not proficient in the Level VI Procedures could be easily be confused by reading the 2021 Level VI Out of Service Criteria. Several entries in the Level VI column contradict each other in Items 1.a. and 1.b. The information in Column 3 needs to be amended to reflect the actions taken during a Level VI inspection.

Request for Action

The Level VI Program Committee needs to revise the Level VI column wording in Items 1.a. and 1.b. Also, the leaking brake chamber language needs to be edited as well as the external brake components.

There is also a brake lining thickness of 1/8" that likely needs to be added to the steering axle brake section as well.

Action Taken by Committee

The Level VI Inspection Program Committee agreed to amend the Level VI Specific column for the entire 20% brake criteria to clarify the “any defective brake” notation to more accurately reflect how it is dealt with during a Level VI Inspection.

Download Download PDF